8100 | 3100 Surface Vertical Rod Exit Devices

8100 Series Life-Safety,  Surface Vertical Rod Exit Devices

3100 Series Fire-Rated, Surface Vertical Rod Exit Devices

The 8100 Series Surface Vertical Rod Exit Device is designed for hollow metal and wood applications that require a life-safety exit device with surface vertical rods for two-point locking.

The 3100 Series Fire-Rated Surface Vertical Rod Exit Device is designed for hollow metal and wood applications that require a fire-rated exit device with surface vertical rods for two-point locking.
Designed for use in applications with single doors or pairs of doors.

Model Type Rating Door Max Size Single Doors Max Size Pairs & Double Egress
3100 SVR 3 hr Hollow metal  4'0" x 10'0"  8'0" x 10'0"
3100 SVR 90 min Wood 4'0" x 10'0"  8'0" x 9'0"
3100T SVR-TRO 3 hr Hollow metal 4'0" x 8'0"  8'0" x 10'0"
3100W SVR-TRO 1-1/2 hr Wood 4'0" x 8'0"  8'0" x 8'0"
3100W SVR-TRO

20 min 

Wood 4'0" x 9'0" 8'0" x 9'0" (std pairs)

 

Certifications: 

ANSI/BHMA A156.3, Grade 1
UL 305 Panic Hardware
3100 Only UL 10C fire-rated, up to 3 hours for non-wood door applications 
CAN/ULC S104 fire door conformant
NFPA 252 fire door conformant

 

Features: 

Materials: Push bar made of extruded aluminum, available in a variety of finishes.

Handing: Device is non-handed.

Push bar Length: Standard sizes: dimensioned for 30" [762 mm], 36" [914.4 mm], 42" [1066.8mm], and 48" [1219.2 mm] openings. Standard width bars can be field cut to the next smallest opening width.

Bar Height: Standard model adjusts from 30" [762 mm] to 44" [1117.6 mm].

Door Height: Standard configuration suitable for doors up to 8' [2.44 m] door, with bar height at 40" [1016 mm] – 44" [1117.6 mm]. For doors up to 10' [3.05 m] use 3055 Tall Door Kit available separately.

Door Thickness: Suits 1-3/4" [44.5 mm] standard, up to 2-1/4" [57.2 mm].

Stile Width: Minimum 3-3/4". Door construction may require additional stile width to meet fire ratings and provide adequate strength.

Projection: 2-15/16" [74.6 mm] when fully projected,1-15/16" [49.2 mm] when dogged.

Dogging: Standard dogging with hex key or with cylinder not available on fire-rated exit devices. Electric dogging option available only.

Fasteners: Standard self-tapping screws and machine screws. Optional Sex Bolt Kits 26-0584 (two required per device). Specify finish.

Cylinders: Select any standard 1-5/32" [29.4 mm] diameter rim cylinder such as the 8736 Rim Cylinder. Available separately.

Cylinder x Fixed Pull Functions: For entry trim function 03 (Night latch - key releases latch) select any standard 1-5/32"[29.4 mm] diameter rim cylinder such as the 8736 Rim Cylinder.  Available separately.

Entry Trim Functions: For entry trim function 08 (key locks/unlocks lever) or function 09 (key releases lever) select any standard 1" [25.4 mm] length, 1-5/32"[29.4 mm] diameter mortise cylinder with MS® cam such as the 4036 Mortise Cylinder. Accommodates cylinder lengths from 1" [25.4mm] to 1-1/4" [31.8 mm]. Available separately.

Bolts and Strikes: The patented top latching mechanism utilizes a rotating top bolt which latches around the header strike, interlocking the door to the frame. Adjustable steel rods protected in contoured covers. The hexagonal, hardened steel bottom bolt is shielded in a cast housing for strength and stability. For wood frames, an additional plate is supplied for securing the header strike.

Standard Package: Individually boxed.

Shipping Weight: 12 lbs [5.44 kg]

 

Options: 

• Available in top rod only version, less bottom rod. Specify by adding “T”after exit device model number.
• Electrification Options: (MLR) Motorized Latch Retraction, Electric Latch Retraction(LR), Alarm, Monitoring
• Mechanical Options: Cylinder Dogging, Matching End Caps

 

Related Products: When purchasing this product, please consider the following related products, available separately:

Accessories Cylinders Trim Power

26-0584 Sex Bolt Kit (two required per device), Tall Door Kit available separately: 8055 for 8100 or 3055 for 3100REX-Monitor/Signal Kits

Operable by either 4036 Mortise Cylinder or 8736 Rim Cylinder depending upon the ANSI/BHMA functions of the exit device. 3080, 3080E Series Entry Trim, 3090-150 Keyless Entry,  3001 Fixed Pull (for hollow metal or wood) PS-EXIT Power Supply4612 Power Transfer Device4603 Rectifier, 4605 Transformer