Description: One amp linear power supply with integrated battery backup circuitry for electric strikes, maglocks, and other access control devices.
Function: Provides filtered and regulated voltage output to power electric strikes, magnetic locks, or other access control devices. Output is selectable in the field for 12 or 24 VDC. Charging circuit is built in for battery backup power (batteries not included) with 12 or 24 VDC operation. LED on circuit board indicates power input.
Specifications:
UL294
Input Power: 110 VAC, 60 Hz, 0.5A
Output Voltage: Field-selectable 12 or 24 VDC, 1 Amp. (Maximum 13.8 VDC/27.6 VDC)
Primary Fuse: 800 mA, 5 x 20MM
Battery Fuse: 2 Amps, 5 x 20MM
Fire Alarm: UL listed low current fire alarm disconnect requires only a minimum size fire alarm relay and wire gauge.
Enclosure: Hinged, steel cabinet measures 12-1/8” x 4” x 12-1/8”. Beige, baked enamel finish with knockouts for conduit and key lock. Sized to accommodate two sealed, lead acid batteries (4AH, not included).
Options: 4612 Power Transfer Device available separately. Enclosure sized to accommodate two sealed, lead acid batteries (4 AH, not included).
Related Products: when purchasing this product, please consider the following related products, available separately:
Compatible Products: This product is compatible with the following products: